Smart Sensor
CSS 014 | DC 24 V

  • Analog/digital interface
  • Small size
  • Easy clip and/or screw fixing
  • High accuracy
  • Quick connection (M12 plug-in connector)
  • Large temperature and humidity range
  • Various application areas (IEC 61010-1/DIN EN 61010-1)

The compact Smart Sensor CSS 014 electronically records temperature and humidity and converts the measured data into a standardized analog 4-20 mA or a digital IO-Link signal. The converted value signals can be utilized or further processed by a control or monitoring unit, e.g. a PLC control. The Smart Sensor is suitable for installation inside and outside the enclosure, even in harsh environmental conditions as can be found in the wind power industry: in shielded outdoor areas and exposed to vibrations.

Technical Data

Download Technical Data Sheet

Download IO-Link Parameter Leaflet for Smart Sensor with IO-Link Interface

Download IODD for Smart Sensor CSS 014 with IO-Link Interface

Download IODD and all accompanying files. Then import IODD file into your control software.

 

 

Measuring signals
analog (4-20 mA)/digital (IO-Link)
digital (IO-Link)

temperature, humidity
events, diagnosis, device data
Max. reaction time3 min.
Load resistance (external)≤ 500 Ω (4-20 mA only)
ConnectionM12 round plug connector, IEC 61076-2-101, 4-pin, A-coded, shielded
Electrical protectionReverse-polarity, short circuit, overvoltage protection
Mountingclip for 35 mm DIN rail, EN 60715 and screw fixing M5
Casingplastic according to UL94 V-0, light grey
Dimensions140 x 40 x 38 mm
Weightapprox. 50 g
Fitting positionvertical (connection on top)
Storage temperature-40 to +85 °C (-40 to +185 °F)
Operating/Storage humiditymax. 90% RH (non-condensing)
Protection type/Protection classIP20 (sensor only IP57) / III (SELV)
ApprovalsVDE and UL File No. E500143 (acc. to IEC 61010-1/DIN EN 61010-1)
NoteOther measuring ranges on request
Art. No.InterfaceOperating voltagePower
consumption max.
Temperature
measuring range
Humidity
measuring range
Operating
temperature
Operating Instructions
01420.2-004-20 mA (analog)DC 24 V
(DC 12-30 V)
1.8 W
(typically 0.4 W)
40 to +60 °C
(-40 to +144 °F)
± 1 K
0 to 100 % RH
± 4%1
-40 to +70 °C
(-40 to +158 °F)
Download
01411.2-00
Download IODD
IO-Link (digital,
specified acc. to version 1.1)
DC 24 V
(DC 18-30 V)
0.3 W-40 to +80 °C
(-40 to +176 °F)
± 0.3 K
0 to 100% RH
± 3%1

-40 to +80 °C
(-40 to +176 °F)

Download

Download IODD and all accompanying files. Then import IODD file into your control software.

¹ Tolerance within 20 to 80 % RH (please request diagram for tolerances outside this range)

Pin assignment

analog 4-20 mA (Art. No. 01420.2-00)
IO-Link (Art. No. 01411.2-00)

Example of Connection

Technical Drawing

(sensor only IP57)